Supply And Commissioning Of Transformer Oil Filter Machine Capacity 300 Lph As Per Following Specificatio N- 1. Flow Capacity- 300 Lph, 2. Operating Temperature- 60 To 80 Degree Centigrade, 3. Supply Voltage 3 Phase 415 Vo Lt 50 Hz Ac 4 Wire, 4 Type Of Filter- Cartridge Filter, 5. After Filtration - Bdv - More Than 60 Kv, Moisture Content <= 20 Ppm, Suspended Particle <= 5 Micron, Gas Content 0.1 % By Volume As Per Requirement, 6. Inlet Pump- A Positive Displ Acement Gear Pump,7. Outlet Pump- A Positive Displacement Gear Pump, 8. Vacuum Pumping System- Rotary Pump Cap Acity- 10 Cu.M/Hour, 9. Heater 6 Kw, System Shall Be Completed With Control Panel, Necessary Pressure Gauge Up To 10 Bar, Thermometer Gauge 60 Degree Centigrade To 100 Degree Centigrade, Flow Meter Of Mccb, System Should Be Clean Ed Removable Of Both Solid Contamination And Liquid Contamination And Moisture And Machine Have Degassing Chamber . Make Sv Engineering, Nach Engineering, Cbs Technologies, Cee Dee Vacuum Equipment, Anc Services. [ Warranty Period: 30 Months After The Date Of Delivery ] ]